Rugged instrumentation for reliable measurement and control

Applications By Industry


 

TCS WP ThumbNew White Paper: Streamlining Temperature Monitoring with High-Density Ethernet Solutions

We discuss the benefits of high-density temperature monitoring systems that utilize Ethernet connectivity compared to traditional systems reliant on individual temperature transmitters. Traditional methods, involving extensive wiring and multiple transmitters, are costly, complex, and inefficient. The TCS Temperature Concentrator System, combined with the HES HART-to-Ethernet Gateway, addresses these challenges by consolidating multiple sensor signals into fewer modules, significantly reducing wiring and equipment costs. The TCS used with the HES leverages Ethernet for faster data transmission, offering enhanced scalability, reduced installation costs, and improved operational efficiency.

More Information

 


TCS latest developments 3High-Density Temperature Monitoring over Ethernet with the TCS Temperature Concentrator System

Our latest update introduces the HES HART®-to-Ethernet Gateway System, which now works seamlessly with our 16-channel TCM Temperature Concentrator Modules. This means you can now enjoy Ethernet-based communication with the TCS. The HES comes in single-channel or 4-channel models and can connect with up to two TCMs per channel. In other words, you can have up to eight TCMs communicating with a single HES, allowing for an astonishing 128 temperature signals to be transmitted over an Ethernet link to a MODBUS/TCP-based host.

More Information


Separator Pressure WP ThumbNew White Paper: Separator Pressure Protection with Simple and Efficient Voting Logic

Take a deep dive into our whitepaper to discover how our solutions are making it easier and safer to monitor pressure in Oil/Water/Gas separators. We'll discuss why it's crucial to monitor pressure in separators and the risks of neglecting it. We'll also explore the importance of implementing robust protection measures, such as Safety Instrumented Systems to ensure optimal performance and safety. Finally, we'll look closer at the advanced features of logic solvers like the SLA Multiloop Logic Solver that can enhance efficiency and reduce risks.

More Information

 


330R2 latest developmentIntroducing the Efficient and Versatile 330R2 1/8 DIN Process and Temperature Panel Meter

We're thrilled to unveil the 330R2 1/8 DIN Process and Temperature Panel Meter, replacing the discontinued 330R Process Monitor. Designed for versatility, the new panel meter boasts universal input and dual process relays, catering to a wide range of process and temperature applications, especially in harsh outdoor environments. With a UV-resistant and sunlight-readable 4-digit display, operating in temperatures ranging from -40 to 65°C, it ensures clarity and durability even in extreme conditions.

More Information


SLA DC WP COVERNew White Paper: Enhancing Efficiency and Safety in Distillation Columns Using Our Latest Logic Solver

Discover how the new breed of Logic Solver from Moore Industries can enhance distillation column safety and efficiency. Learn how our SLA Multiloop Logic Solver addresses temperature stratification challenges, offering cost-effective monitoring, alarming, and shutdown capabilities across multiple zones compared to Safety-PLCs. See how the SLA could improve safety and efficiency in your safety applications, ensuring optimal performance and protection for your safety loops.

More Information

 


SLA WP CoverNew White Paper: SIS Logic Solvers More Choices are Needed

We explore the gap between single-loop Logic Solvers and larger safety systems, introducing innovative solutions that bridge this divide. Our discussion covers crucial factors for selection, encompassing performance, cost-effectiveness, ease of programming, open communication protocols, cybersecurity, and operational characteristics. By the end, you'll be equipped with the knowledge to make informed decisions when choosing the ideal Logic Solver for your Safety Instrumented System, ensuring the utmost safety for your industrial processes.

More Information

 


latest development slaSLA Multiloop and Multifunction Safety Logic Solver and Alarm

Moore Industries announces the new SLA Multiloop and Multifunction Safety Logic Solver and Alarm. The SLA is part of the Moore Industries FS FUNCTIONAL SAFETY SERIES, the exida® certified SIL 2/3 capable SLA is a versatile multiloop and multifunctional Safety Logic Solver and Alarm that acts on hazardous process conditions, warns of unwanted process parameters, performs on/off control and provides emergency shutdown in Safety Instrumented Systems (SIS) and traditional alarm trip applications. The FDT/DTM programmable 4-wire (line/mainspowered) SLA accepts up to four discrete and six analog inputs from a wide array of devices and sensors including: Current and Voltage Signals, Temperature (RTD and T/C) Sensor Inputs, Resistance and Potentiometer Devices, Direct Millivolt Sources, and Low Voltage Contacts.

More Information


TMZ MODBUS Transmitter now with Dual Universal Inputs Moore IndustriesTMZ MODBUS Transmitter now with Dual Universal Inputs

Moore Industries announces the new TMZ PC-Programmable MODBUS Transmitter with Dual Universal Input channels. The TMZ Dual Universal Input (2PRG) model accepts most industry standard current, voltage, RTD and thermocouple type sensors along with resistance and potentiometer inputs. It allows users to increase density and reduce costs by doubling monitoring capability in a single unit. Because the TMZ has digital MODBUS output, the error typically associated with Analog-to-Digital converters for units with analog outputs is eliminated.

More Information


Panels and SystemsInstrument Panels and Systems Engineering, Design and Build

Custom instrument panels, enclosures and systems by Moore Industries eliminate the need to specify, procure, and assemble multi-vendor instrumentation and hardware. Moore Industries is an expert in designing and building compact and modular solutions used to monitor temperature, pressure, level, flow and safety related processes with high performance instrumentation and components. Instrumentation, cabinets, wiring, tubing, relays, power supplies—whatever is required—Moore Industries can supply and assemble a ready-to-install instrument sub-systems for your control and monitoring needs.

More Information


ECT skinnyRugged ECT DIN Signal Isolator/Converter Now In a Thin 15mm Housing

The UL Approved ECT-DIN 2-Wire Isolator is now available in a narrow 15mm aluminum housing. The thinner ECT-DIN 2-Wire Isolator with 15mm width retains the same General and Hazardous area approvals as the rest of the ECT family of isolators. It also has the same RFI/EMI protection and -40°C to 85°C operating temperature range. The ECT-DIN 2-Wire Isolator can be installed in hazardous locations and does not require installation in climate-controlled environments, making it perfect for more extreme locations. Its narrow size allows more isolators to fit in cabinets and field enclosures where installation space is a premium, and ideal is ideal for utilizing existing field mounted cabinets.

More Information


NCS MAANet Concentrator System with New -MAA Multipoint Analog Alarm Option

The NET Concentrator System® (NCS) has a new versatile Multipoint Analog Alarm (–MAA) option that allows users to quickly set up simple or dynamic alarming schemes. The -MAA option utilizes a built-in ISaGRAF program providing a flexible alarm configuration that is accessed via easy to use web pages through the on-board web server. With the -MAA option, the NCS allows users to configure up to 32 alarms. Each alarm can be freely assigned to any of the eight relay outputs on the Relay Output Module (ROM). This enables each relay output to be driven by one input/alarm or multiple inputs/alarms. Each alarm can be configured as high or low with its own deadband setting and can optionally include alarming on any NCS system faults.

More Information


HES newsIntroducing the HES HART to Ethernet Gateway System

Timely knowledge about your process enables better decisions and faster preventive action. Get the process detail you need from your Smart HART devices to MODBUS/TCP and HART-IP based monitoring and control systems at the speed of Ethernet with the HES HART to Ethernet Gateway System from Moore Industries. Connect up to 64 Smart HART devices to the HES and collect the Dynamic and Device Variables, along with diagnostics, from each device that helps deliver critical information needed to help you address process and device problems before they turn into unplanned downtime.

More Information


STZ AISAssociated Intrinsic Safety Option Added to the SIL3 capable STZ DIN model Temperature Transmitter

Continuing the expansion of our Associated Intrinsically-Safe product family, the NEW Associated IS option is also available for the Functional Safety SIL2/3 capable STZ DIN-Rail model dual-input temperature transmitter. With this new option you can now directly connect sensors located in Class I Div 1/Zone 0/1 hazardous areas to the STZ-DIN model. It provides the necessary protection typically afforded by an intrinsically-safe barrier in plants or facilities where the method of protection is Intrinsic Safety.


THZ3 STZ AISIntroducing the Associated Intrinsic Safety option for the THZ3 DIN model Temperature Transmitter

Our Associated Intrinsic-Safety family just keeps getting better: Introducing the NEW Associated IS option for the THZ3 DIN-Rail model dual-input temperature transmitter. Now added to all the amazing features of the THZ3 is the ability to connect sensors located in Class I Div 1/Zone 0/1 hazardous areas directly to the THZ3-DIN when the -AIS option is included. This new option features a built-in intrinsically safe field connection that provides the necessary protection typically afforded by an intrinsically-safe barrier in plants or facilities where the method of protection is Intrinsic Safety.

More Information


SLD What's New Moore IndustriesIntroducing the SLD Functional Safety Programmable Loop Display

The SIL3 capable SLD features a large integral display that shows real-time process status in mA, percent, or any designated 5-character Engineering units (EGU). The latest addition to the Moore Industries’ FS Functional Safety Series products, it is certified by exida® as a SIL3 capable, non-interfering device for use in a safety loop. The SLD is the perfect solution to accurately and reliably display process status in a safety loop, and features the Loop Maintenance Diode Option which allows it to be removed from the safety loop without affecting the integrity of the safety function.

More Information


SFY Moore IndustriesSFY Functional Safety Frequency-to-DC Transmitter with Display

Our newest addition to the ever-expanding FS Functional Safety Series line is the SIL 3 capable SFY Functional Safety Frequency-to-DC Transmitter with Display. The SFY provides a high level of availability for safety-critical applications and for use as a component part of a safety instrumented system. It monitors the signal, outputting the selected variable (frequency, period, high pulse width, low pulse width or contact closure) both to its display and to a 4-20mA signal that is linear and input-scalable. It features a large integral display that shows real-time process status. The SFY programs in less than a minute to accept varying frequency signals from AC or DC flow measurement devices such as turbine meters and magnetic pick-up coils.

More Information


spa2isSPA2IS Programmable Limit Alarm Trips with Intrinsically-Safe Field Connections

The SPA2IS Programmable Limit Alarm Trips provide on/off control, warn of unwanted process conditions, alarm on rate-of-change and provide emergency shutdown. The newest member of the Moore Industries Limit Alarm Trips and Switches product line, the versatile SPA2IS accepts signal inputs from transmitters and temperature sensors that are located in hazardous areas where the method of protection implemented by the plant or facility is Intrinsic Safety. Normally such installations would require the additional use of an intrinsically-safe barrier. The SPA2IS, however, features built-in intrinsically-safe field connections that provide the necessary protection typically afforded by a galvanically isolated intrinsically-safe barrier.

More Information


STZ Family What’s New Moore IndustriesSTZ Functional Safety Dual Input Smart HART Temperature Transmitter

The SIL 3-capable STZ Functional Safety Smart HART Temperature Transmitter is a dependable and accurate temperature transmitter for use in Safety Instrumented Systems (SIS) where dangerous processes occur. Part of the FS Functional Safety Series, the STZ was designed and built from the ground up to ensure conformance with strict IEC 61508:2010 standards for safety-related applications. The STZ offers a dual sensor input that reduces process interruptions. Backup and Fail-Over Protection allows either of the sensors or inputs to be designated as the primary measurement, with the secondary input acting as the backup sensor in case of primary sensor failure.

More Information


THZ3 TDZ3 Family Whats New Moore IndustriesTHZ3 and TDZ3 Dual Input Smart HART Temperature Transmitter

The THZ3 and TDZ3 mark the next generation of our Smart HART® temperature transmitters. These products have Moore Industries’ industry leading durability and reliability combined with several new features that increase usability and functionality including a new dual sensor input. The dual sensor input allows the THZ3 and TDZ3 to offer backup and fail-over protection, with either of the sensors or inputs designated as the primary measurement and the secondary input acting as a backup sensor in case of a primary sensor failure. The THZ3 and TDZ3 come with Device Intelligence, a series of features for smarter control and monitoring including sensor drift and corrosion detection, smart range alarms with four HART alarms, a High Availability option and input simulation capability allowing manual input of a direct or calculated value.

More Information


SSX SST Family Latest Development Moore IndustriesSSX/SST Safety HART Isolators/Splitters

The newest members of our FS Functional Safety Series, the SSX and SST Safety Isolators and Splitters, provide reliable isolation and signal conversion for HART® data in functionally safe process control settings. They protect safety systems by isolating an SIS from basic process control or monitoring systems so that disconnections or other failures don’t impact the safety system. The two-wire (loop powered) SSX and four-wire (line/mains powered) SST were developed following the strict IEC 61508:2010 standards for safety-related applications and are certified by exida for single use in Safety Instrumented Systems up to SIL 2.

More Information


SRM SIL2 Latest Development Moore IndustriesSRM Safety Relay Module

A new member of our FS Functional Safety Series, the exida IEC 61508 SIL 2 certified SRM Safety Relay Module accepts a single contact closure input from a logic solver trip output such as the STA Safety Trip Alarm or SPA2 Programmable Limit Alarm Trip. It provides three contacts per alarm input, allowing the addition of alarm contacts for a safety process without special installation or configuration.

More Information


Bullet CoverWhy Wait? Pull the Trigger NOW!

The BULLET® WirelessHART® Adapter by MACTek, and supplied by Moore Industries, enables new and existing wired smart HART field devices, non-smart analog field devices (i.e., 4-20mA) and remote HART I/O from any supplier to communicate with host applications using WirelessHART Technology.

Use The BULLET with our Single and Multi-Channel Smart HART Temperature Transmitters, our HTZ Smart HART Humidity and Temperature Transmitter and our non-smart analog Signal Isolators, Transmitters and Converters. We also offer complete wireless packages that include one or multiple instruments, an enclosure and the BULLET.

More Information

 

 


SIL3 white cover

STA Safety Trip Alarm from Moore Industries SIL 2 and SIL 3 Certified to IEC 61508 by exida

The STA Safety Trip Alarm from Moore Industries has been certified by exida for Safety Instrumented Systems to IEC 61508:2010 for systematic integrity up to SIL 3 and for random integrity up to SIL 2. This means that that the STA is approved for single use in Safety Instrumented Systems up to SIL 2 and in redundant architecture such as 1oo2 and 2oo3 up to SIL 3. Approval from exida provides independent verification of the integrity of the STA from a leader in industrial safety certifications and ensures that it meets the industry safety standards specified in IEC 61058: Parts 1, 2 and 3. As part of its certification of the STA, exida measured the effectiveness of the product development process prevent systematic failures along with its strength at protecting against random failures. Certification of the STA by exida ensures product quality and reliability for customers along with reducing risks and lowering lifecycle costs.

More Information


IBOX Whats New

NEW I-BOX Surface-Mount Instrument Enclosure 

Ideal for indoor installations, the I-BOX high-impact, light weight and chemical resistant enclosure safeguards instruments and electrical components even under demanding conditions. The I-BOX is available in standard internal widths of 9, 12 and 15 inches, with depths of 3 and 6 inches. It mounts securely on a surface using standard, key-slotted mounting holes, and versatile internal mounting plate accommodates any type of Hat or G-type DIN-rail. Alternatively, surface-mount instruments and components can be installed directly onto the plate, which is suitable for grounding. 

More Information


WNM What's New

NEW Wireless Network Module for the NET Concentrator System®EW Wireless Network Module for the NET Concentrator System®

When wires can’t be run for practical or economic reasons, the WNM Wireless Network Module provides accurate and reliable point-to-point wireless connectivity between remote field sites. The WNM is the perfect for creating high-integrity wireless networks when paired with our NCS NET Concentrator System Process Control and Distributed I/O or similar SCADA and distributed I/O systems.

More Information


SPA2 Glove What's New

The Best Got EVEN Better

Our SPA2 Programmable Limit Alarm Trip earned its reputation as the industry standard by delivering steadfast, yet affordable, operation year in and year out. Now… the best just got EVEN better. Our SPA2 provides all of the features you’ve counted on, and much more. The SPA2 now features Enhanced RFI/EMI Protection as standard and a Universal Power Supply. Just hook it up to an ac (21.6-375Vdc) or dc (90-260Vac) power supply, and you’re up and running! 

More Information


EMM What's New

Update to NCS NET Concentrator System Increases Flexibility for MODBUS RTU and Ethernet Communications

We’ve updated our NET Concentrator System® (NCS) to provide you with increased options for communications. The process control and distributed I/O network now comes standard with an Ethernet (MODBUS/TCP) port and dual, independent MODBUS RTU (RS-485) ports. One or both of the MODBUS RTU ports can be configured as MODBUS master ports, allowing the NCS to poll other MODBUS RTU slaves with the network polling functions of a typical MODBUS master.

More Information  


Power Plant Cover

NEW Interactive Line Card for Automation and Instrumentation Solutions for Power Plant Applications 

Today’s mature power plants present unique challenges when performing maintenance, repair, replacements and upgrades. Often, companies that provided in-place instrumentation are long gone. Monitoring and control requirements may have changed. More, and better, process information is needed to improve operations and profitability. We offer a full range of sensors, instrumentation and data communication systems that help you replace and link legacy instruments with existing equipment and with new control strategies.

More Information

 


TPS 400 Moore Industries

Fieldbus Power Supply Delivers Up to 500mA

The TPS400 TRUNKGUARD® Fieldbus Power Supply provides isolated, conditioned power to up to four FOUNDATION fieldbus™ H1 Segments. It is ideal for use with MooreHawke Series 200 and Series 300 TRUNKGUARD Fieldbus Device Couplers, as well as any other manufacturer’s non-intrinsically-safe Fieldbus device couplers.

More Information

 

 


STA What's New

SIL 2 Compliant Safety Trip Alarm TÜV Certified to IEC 61508

Part of our FS FUNCTIONAL SAFETY SERIES, the STA Safety Trip Alarm performs as a logic solver and acts on potentially hazardous process conditions; warns of unwanted process conditions; provides emergency shutdown, or provides on/off control in Safety Instrumented Systems (SIS) and traditional alarm trip applications. 

More Information

 


MNCS What's New

NEW MODBUS Master and Distributed I/O System 

The microNCS MODBUS RTU Master and Distributed I/O System provides a real-time gateway between the field or factory floor and your control strategy. The newest member of our NCS NET Concentrator System® family of intelligent distributed I/O, the microNCS delivers four or eight analog inputs, four discrete inputs, and dual MODBUS RTU ports that can be configured as MODBUS master ports.

More Information


TCS What's New

Cut Costs of Transmitting Multiple Temperature Sensor Measurements  

With our new TCS Temperature Concentrator System™ Multi-Channel Transmitter, you can "concentrate" up to 32 signals onto one network and economically transmit the data long distances via HART or MODBUS RTU digital communications.

More Information


HTZ Our Latest Development

HART Transmitter Delivers Precision Relative Humidity MeasurementsHART Transmitter Delivers Precision Relative Humidity Measurements 

For fast and simple set up, our new precision HTZ Smart HART Humidity and Temperature Transmitter can be programmed and queried from any point on the 4-20mA wires using a standard HART Communicator. It’s the ideal humidity measurement solution for industrial, commercial, manufacturing, and HVAC applications.

More Information