Product Information

Moore Industries’ temperature transmitters allow you to take a weak, low-level RTD or thermocouple temperature sensor signal, and convert it to a high-level analog signal more appropriate for long-distance transmission through a loud plant, and prepared for direct interface with an indicator, recorder, PLC, DCS or PC-based SCADA system.

For more information on utilizing temperature transmitters and sensors to enhance the functionality of your process, go to Problem Solvers Application Ideas.

Detailed product data sheets are available in PDF format by clicking on the product names below. PDF files require Adobe Reader, which can be downloaded from Adobe's Web site.

Featured Interface Solutions

Unit

Input

Output

Power

Mounting

Features

TRY Isolated and TRX Non-Isolated 2-Wire PC-
Programmable Temperature Transmitters


Get Product Information and Installation Tools

TRY

TRX

Sets Up in One Minute, from One Software Window

RTD
2-, 3-, 4-Wire
Platinum, Copper, Nickel

Thermocouple
J, K, E, T, R, S, N, C, B

Ohms
0 to 4000 ohms

Millivolts
-50 to +1000mV

Averages and Differentials

4-20mA

2-Wire, Loop-Powered
(10-42Vdc for TRY)
(8-42Vdc for TRX)
High-Density and RFI Resistant
Aluminum DIN-style
(G-type and Top Hat rails)

Field Mount
Hockey-Puck (head, pipe, relay-track, surface, and explosion-proof)

Universal 2-wire programmable analog plant standard

PC-programmable with FREE software and cable

Exceptional accuracy for demanding applications

Fast measurement cycle, up to 8 times per second


Universal Flexible Temperature Sensor Installs Without Removing Temperature Transmitter Enclosure or Thermowell Components: The WORM® flexible RTD and thermocouple temperature sensors for thermowell Temperature Assemblies replace restrictive, straight sensor probes with a universal sensor strategy that will save time and money. Its unique, flexible design installs in minutes.

Get Data Sheet (PDF, 2.1M)

The WORM is now available in Ready-to-Install Temperature Assemblies for Surface Measurements. They clamp, bolt or weld directly to tanks, pipes, motors, compressors, reactors or anywhere else a skin (surface) temperature sensor measurement is needed.

Get Data Sheet
rti3.pdf (1.5M)


Unit 

Input

Output

Power

Mounting

Features

TDY Isolated 2-Wire PC-Programmable Temperature Transmitters with Display


Get Product Information and Installation Tools

Easy-to-Read Digital Display

RTD
2-, 3-, 4-Wire
Platinum, Copper, Nickel

Thermocouple
J, K, E, T, R, S, N, C, B

Ohms
0 to 4000 ohms

Millivolts
-50 to +1000mV

4-20mA

2-Wire,
Output Loop-Powered
(10-42Vdc)
Ready-to-Install
Field-Mount Temperature Transmitters and Hockey-Puck (head-mount) housing for standard connection heads

Universal 2-wire programmable analog plant standard

PC-programmable with FREE software and cable

Customizable display shows process status/diagnostics

Exceptional accuracy for critical applications

Fast measurement cycle, up to 8 times per second

Unit 

Input

Output

Power

Mounting

Features


THZ2 & TDZ2 Isolated
2-Wire Smart HART Temperature Transmitters


Get Product Information and Installation Tools

Programmable via HART Communicator or Intelligent PC Software

RTD
2-, 3-, 4-Wire
Platinum, Copper, Nickel

Thermocouple

J, K, E, T, R, S, N, C, B

Ohms

0 to 4000 ohms

Millivolts
-50 to 1000mV
Standard, Easy-to-Read Process Displays
4-20mA output with superimposed HART digital protocol signal

 

2-Wire,
Loop Powered
(12-42Vdc or 12-28Vdc for IS applications)
Field-Mount Dual-Compartment and Hockey-Puck with Complete Temperature Transmitters Assemblies
(head, pipe, relay-track, surface and explosion-proof)

High-Density and RFI Resistant
Aluminum DIN-style
(G-type and Top Hat rails)

HART and analog communication

Programs with HART communicator, host or FREE PC software and cable

Customizable display shows process status/diagnostics (TDZ2)

20-bit input resolution delivers exceptional digital accuracy

Long-term stability, up to 5 years between calibrations



Ready-to-Install Temperature Transmitters Save Time and Money: Why shop around for pieces and parts? Our easy-to-order temperature transmitters arrive tested, calibrated, and ready to install. Very affordably priced, these temperature transmitters feature our user-friendly and universal temperature transmitters perfectly matched to the RTD or thermocouple temperature sensor, thermowell and fittings you use most.

RTI-1 Ready-to-Install Sensor, Temperature Transmitters and Thermowell Assemblies (PDF, 1.7M)
RTI-2 Ready-to-Install Sensor, Temperature Transmitters and Thermowell Assemblies with Display (PDF, 1.4M)
RTI-3 Ready-to-Install Sensor, Temperature Transmitters Assemblies for Surface Measurements (PDF, 1.5M)
Temperature Transmitters - Monitoring Assemblies for Hi-Tech Facility & Process Control (PDF, 1.0M)

Unit 

Input

Output

Power

Mounting

Features

TFZ Programmable FOUNDATION Fieldbus Temperature Transmitters




Get Product Information and Installation Tools
Programs to accept

RTD
2-, 3-, 4-Wire Platinum, Copper, Nickel

Thermocouple
J, K, E, T, R, S, N, B, C

Ohms
0 to 4000 ohms

Millivolts
-50 to +1000mV

Standard, Easy-to-Read Process Display
FOUNDATION Fieldbus Communications
2-Wire, Loop-Powered
(9-32Vdc)
Ready-to-Install
Field-Mount Temperature Transmiters and Hockey-Puck (head-mount) housing for standard connection heads

FOUNDATION fieldbus communication

Remote programming from fieldbus host

Customizable display shows process status/diagnostics

20-bit input resolution for exceptional digital accuracy

Long-term stability, up to 5 years between calibrations

Delivers valuable fieldbus diagnostics


Unit 

Input

Output

Power

Mounting

Features

TPZ Isolated 2-Wire PC-
Programmable Temperature Transmitters with Display




Get Product Information and Installation Tools

Programs to accept

RTD
2-, 3-, 4-Wire
Platinum, Copper, Nickel
Thermocouple
J, K, E, T, R, S, N, B, C
Ohms

0 to 4000 ohms

Millivolts
-50 to +1000mV

Standard, Easy-to-Read Process Display
PROFIBUS PA Communications
2-Wire, Loop-Powered
(9-32Vdc)
Ready-to-Install
Field-Mount Temperature transmitters and Hockey-Puck (head-mount) housing for standard connection heads

PROFIBUS PA communication

Remote programming from fieldbus host

Customizable display shows process status/diagnostics

20-bit input resolution for exceptional digital accuracy

Long-term stability, up to 5 years between calibrations

Delivers valuable fieldbus diagnostics

Unit

Communication

Transmission

Power

Frequency

Option

Housing

BULLET WirelessHART Adapter by MACTek

BULLET WirelessHART Adapter by MACTek

Get Product Information and Installation Tools

Platform:
WirelessHART capable network

Compliance:
Fully compliant HART 7.1 device. Backward compatible to HART 5 devices

HART
Sub-Devices:

Supports up to 8 wired HART sub-devices

RF Range: 235 meters outdoors, open air (normal)


RF Output Power: 10dBm

Series Loop Voltage Drop:
1.0Vdc-2.5Vdc (user-selectable in 0.5Vdc steps)

Series Loop Operating Current: 3.2mA to 25mA DC operating; Protected against over-voltage, over-current and reverse connections

External Power Operating Voltage:+7Vdc to +32Vdc; Reverse voltage protection

External Power Operating Current:<1mA; Maximum, 25mA

2.4GHz

Multidrop (Direct Power): 32mA DC maximum, 8 devices at 4mA DC; or 1 TCM

Multidrop (Loop Power): 24mA DC maximum, 6 devices at 4mA DC; or 1 TCM

Loop Current Monitoring Range: 3.2mA to 22mA DC, 1% Accuracy

Body:Aluminum alloy, RoHS corrosion coating, polyurethane enamel paint

Dome: Proprietary resin

Physical Connection:One, Male ½-inch NPT with internal poured seal

Electrical Connection:5 lead wires x 600mm (24-inch) long, exiting from male ½-inch NPT Opening

Ground: External earth grounding screw


Unit 

Input

Output

Power

Mounting

Features

TCS Temperature Concentrator System™ Multi-Channel Temperature Transmitters


Get Product Information and Installation Tools
16 Input Channels Individually Program to accept

RTD
2-, 3-, 4-Wire
Platinum, Copper, Nichel

Thermocouple
J, K, E, T, R, S, N, C, B

Ohms
0 to 4,000 ohms

Millivolts
-50 to 1000mV

HART
Digital Communications Protocol

-or-

MODBUS RTU
(RS-485)
with the HMC HART-to-MODBUS Converter Module
TCS Module, 2-Wire, Loop-Powered (15-42Vdc or 15-30Vdc for IS applications)

HMC Module, 4-Wire,
Line-Powered (20-30Vdc)

High-Density and RFI Resistant Aluminum DIN-style (G-type and Top Hat rails)

HART or MODBUS RTU communications

16 channels are individually configurable

Installs in hazardous areas

Substantially reduce hardware, wire, installation and I.S. barrier costs

Unit 

Input

Output

Power

Mounting

Features

HTZ Smart HART Humidity and Temperature Transmitters




Get Product Information and Installation Tools
Programs to Simultaneously Measure Humidity and Temperature
Standard, Easy-to-Read Process Display with Dual Isolated 4-20mA Outputs Proportional to Relative Humidity, Ambient Temperature or Dew Point (User-Selectable)

 

2-Wire, Loop-Powered
(12-42Vdc)
Surface, Pipe and Duct-Mount Enclosures (NEMA 4X, IP66)

Programmable dual analog outputs

Programs with HART communicator, host or FREE PC software and cable

Process display mounts up to 9m (30ft) from the measurement location

High accuracy humidity, temperature and dew point measurements

Unit 

Input

Output

Power

Mounting

Features

CPT Isolated 4-Wire Site-Programmable Temperature Transmitters


Get Product Information and Installation Tools
Sets Up in One Minute, from One Software Window

RTD
2-, 3-, 4-Wire
Platinum, Copper, Nickel

Thermocouple
J, K, E, T, R, S, N, C, B

Ohms

0 to 4000 ohms

Millivolts
-50 to +1000mV

Current and voltage inputs are also available. See the data sheet for details.
Sets Up in One Minute, From One Software Window

Current
Any range from 0 to 20mA including: 0-20mA 4-20mA

Voltage
Any range from 0 to 10Vdc including:
1-5Vdc
0-10Vdc

Optional Relay Output Warns of Unwanted Process Conditions    
High/Low Alarms
(Failsafe or Non-Failsafe)

 

4-Wire,
Line-Powered
(24Vdc, 117Vac, 230Vac or 12DC)
High-Density and RFI Resistant
Aluminum DIN-style
(G-type and Top Hat rails)

Universal 4-wire programmable analog plant standard

PC-programmable with FREE software and cable

User-selectable failure mode for upscale or downscale drive

Optional relay output for process alarming

Unit 

Input

Output

Power

Mounting

Features

SPT Isolated 4-Wire Site-Programmable Temperature Transmitters


Get Product Information and Installation Tools
Selectable with On-Board Controls and Display Prompts

RTD
2-, 3-, 4-Wire
Platinum, Copper, Nickel

Thermocouple
J, K, E, T, R, S, N, B

Ohms
0 to 4000 ohms

Millivolts
-10 to +120mV

Averages and Differentials
Selectable with On-Board Controls and Display Prompts
4-20mA
(source or sink)
1-5Vdc

Combination Temperature Transmitters and Alarm with Optional Alarm Output
Single Relay

 

Takes any Power Supply
4-Wire,
Universal Powered
(accepts 22-300Vdc or 90-260Vac)
High-Density and RFI Resistant
Aluminum DIN-style
(G-type and Top Hat rails)

Universal 4-wire programmable analog plant standard

Configures using front panel pushbuttons

Customizable display shows process status/diagnostics

Universal AC/DC power input

Optional relay output for process alarming

Unit 

Input

Output

Power

Mounting

Features

TMZ 4-Wire PC-Programmable MODBUS Temperature Transmitters


Get Product Information and Installation Tools
Sets Up in One Minute, from One Software Window

RTD
2-, 3-, 4-Wire
Platinum, Copper, Nickel

Thermocouple
J, K, E, T, R, S, N, C, B

Ohms
0 to 4000 ohms

Millivolts
-50 to +1000mV

Current and voltage inputs are also available. See the data sheet for details.
MODBUS RTU
(RS-485)
Communications

 

4-Wire,
Line Powered
(24Vdc)
High-Density and RFI Resistant
Aluminum DIN-style
(G-type and Top Hat rails)

Industry-standard MODBUS RTU communication

Up to 32 can be multi-dropped onto a low-cost communication link

PC Programmable with FREE PC software and cable

Unit 

Input

Output

Power

Mounting

Features

RIY Isolated 2-Wire Site-Programmable RTD Temperature Transmitters


Get Product Information and Installation Tools
Selectable with On-Board Controls and Display Prompts

RTD
2-, 3-, 4-Wire
Platinum, Copper, Nickel

Ohms
0 to 4000 ohms

Average and Differential
4-20mA

 

2-Wire, Output Loop-Powered (12-42Vdc)
High-Density and RFI Resistant
Aluminum DIN-style
(G-type and Top Hat rails)

Field Mount
Hockey-Puck (head, pipe, explosion-proof, surface, and relay track)

Programmable analog communication

Configures using front panel pushbuttons

Customizable display shows process status/diagnostics

Diagnoses RTD failure and which wire is broken

Unit 

Input

Output

Power

Mounting

Features

TIY Isolated 2-Wire Site-Programmable Thermocouple Temperature Transmitters


Get Product Information and Installation Tools
Selectable with On-Board Controls and Display Prompts

Thermocouple
J, K, E, T, R, S, N, B
Millivolts
-10 +75mV
4-20mA

 

2-Wire, Loop-Powered (12-42Vdc)
High-Density and RFI Resistant
Aluminum DIN-style
(G-type and Top Hat rails)

Field Mount
Hockey-Puck (head, pipe, explosion-proof, surface, and relay track)

Programmable analog communication

Configures using front panel pushbuttons

Customizable display shows process status/diagnostics

Long-term accuracy via automatic reference junction compensation

Unit 

Input

Output

Power

Mounting

Features

T2X-DWB Wall-Mount Room Air Temperature Monitoring System


Get Product Information and Installation Tools
Programs to accept
RTD

High-Accuracy Pt 3850,
1000 ohm
4-20mA

 

2-Wire, Loop-Powered (8-42Vdc)
Mounts Directly to a Wall or Surface

Simple wall mount installation

PC-programmable with FREE software and cable

High-accuracy 1000 ohm RTD for room temperature sensing

Sensor placement and venting design allows for maximum air flow