| Featured Interface Solutions |
| Model |
Input |
Output |
Power |
Mounting |
|
ECT-DIN 2- and 4-Wire Signal Isolators, Converters, Repeaters, and Splitters
Get Data Sheet
ect_din.pdf (166K ) |
4-20mA
1-5Vdc
0-150Vac
0-5Aac
|
4-20mA
Dual Output Channels for Signal Splitting
|
2-Wire,
Output Loop-Powered
(10-42Vdc)
2-Wire,
Input Loop-Powered
(5.5 volts loop-powered)
4-Wire,
Line-Powered
(24Vdc, 117Vac, or 230Vac)
|
High-Density and RFI Resistant
Aluminum DIN-style
(G-type and Top Hat rails)
|
|
SIY 2-Wire PC-Programmable Signal Isolator and Converter
Get Data Sheet
siy.pdf (397K ) |
Sets Up in One Minute, From One Software Window
Current
Any range from -2.5 to 55mA including:
0-20mA
4-20mA
10-50mA
Voltage
Any range from -0.5 to 11V including:
1-5Vdc
0-10Vdc
|
4-20mA
|
2-Wire,
Output Loop-Powered
(10-42Vdc)
|
High-Density and RFI Resistant
Aluminum DIN-style
(G-type and Top Hat rails)
Field Mount
Hockey-Puck
(head, pipe, relay-track, surface, and explosion-proof)
|
|
SIX 2-Wire Signal Isolator, Converter, and Repeater
Get Data Sheet
six.pdf (130K ) |
0-20mA
4-20mA
10-50mA
0-1mA
-1 to +1mA
-10 to +1-Vdc
0.2-1Vdc
0-1Vdc
0-5Vdc
1-5Vdc
0-10Vdc
0-30Vdc
|
4-20mA
10-50mA
|
2-Wire,
Output Loop-Powered
(12-42Vdc)
|
High-Density and RFI Resistant
Aluminum DIN-style
(G-type and Top Hat rails)
|
|
CPT
4-Wire PC-Programmable Signal Isolator and Converter
Get Data Sheet
cpt.pdf (356K )
|
Sets Up in One Minute, From One Software Window
Current
Any range from 0 to 50mA including:
0-20mA
4-20mA
10-50mA
Voltage
Any range from 0 to 10Vdc including:
1-5Vdc
0-10Vdc
Sensor (RTD and T/C) inputs are also available. See the data sheet for details.
|
Sets Up in One Minute, From One Software Window
Current
Any range from 0 to 20mA including:
0-20mA
4-20mA
Voltage
Any range from 0 to 10Vdc including:
1-5Vdc
0-10Vdc
Optional Relay Output Warns of Unwanted Process Conditions
High/Low Alarms
(Failsafe or Non-Failsafe)
|
4-Wire,
Line-Powered
(24Vdc, 117Vac, or 230Vac)
|
High-Density and RFI Resistant
Aluminum DIN-style
(G-type and Top Hat rails)
|
|
TMZ
4-Wire PC-Programmable MODBUS Signal Transmitter
Get Data Sheet
TMZ.pdf (308K )
|
Sets Up in One Minute, From One Software Window
Current
Any range from 0 to 50mA including:
0-20mA
4-20mA
10-50mA
Voltage
Any range from 0 to 10Vdc including:
1-5Vdc
0-10Vdc
Sensor (RTD and T/C) inputs are also available. See the data sheet for details.
|
MODBUS RTU (RS-485) Communications
|
4-Wire,
Line-Powered
(24Vdc)
|
High-Density and RFI Resistant
Aluminum DIN-style
(G-type and Top Hat rails)
|
|
FCT 4-Wire Field-Configurable Signal Isolator and Converter
Get Data Sheet
fct.pdf ( 81K ) |
Field Configurable
0-20mA
4-20mA
0-50mA
10-50mA
0-5Vdc
1-5Vdc
0-10Vdc
Special Ranges
|
Field Configurable with Jumpers
0-20mA
4-20mA
0-5Vdc
1-5Vdc
0-10Vdc
Special Ranges
|
Takes any Power Supply
4-Wire, Universal Line-Powered
(accepts 22-300Vdc or 90-260Vac)
|
High-Density and RFI Resistant
Aluminum DIN-style
(G-type and Top Hat rails)
|
|
HIT and HIX 2- and 4-Wire HART® Isolators
Get Data Sheet
hit_hix.pdf (571K ) |
4-20mA
input with superimposed HART digital protocol signal
|
Isolates Loop, Lets HART Digital Signal "Pass Through"
4-20mA
output with superimposed HART digital protocol signal
|
HIT
4-wire line-powered
(24Vdc, 117Vac, 230Vac)
HIX
2-wire loop-powered
(12-42DC)
|
Thermoplastic DIN-style
(G-type and Top Hat rails)
|
|
SCX 2-Wire Signal Isolator and Converter
Get Data Sheet
scx.pdf (159K ) |
4-20mA
10-50mA
|
4-20mA
10-50mA
Special Ranges
|
2-Wire,
Input Loop-Powered
(5.5, 4.5, or 8.5 volts loop powered)
|
High-Density and RFI Resistant
Aluminum DIN-style
(G-type and Top Hat rails)
Field-Mount
Hockey-Puck
(head, pipe, relay-track, surface, and explosion-proof)
|
|
ACX 2-Wire AC Current Isolator and Transmitter
Get Data Sheet
acx.pdf (123K ) |
0-1Aac
0-2Aac
0-3Aac
0-4Aac
0-5Aac
0-0.5Vac
0-1.5Vac
0-5Vac
0-10Vac
0-25Vac
0-50Vac
0-120Vac
0-150Vac
|
4-20mA
10-50mA
|
2-Wire,
Output Loop-Powered
(10-42Vdc)
|
High-Density and RFI Resistant
Aluminum DIN-style
(G-type and Top Hat rails)
Field-Mount
Hockey-Puck
(head, pipe, relay-track, surface, and explosion-proof)
|
|
SDY 2-Wire PC-Programmable Signal Isolator and Converter with Display
Get Data Sheet
sdy.pdf (296K ) |
Sets Up in One Minute, From One Software Window
Current
Any range from -2.5 to 55mA including:
0-20mA
4-20mA
10-50mA
Voltage
Any range from -0.5 to 11V including:
1-5Vdc
0-10Vdc
|
Easy-to-Read Display
4-20mA
|
2-Wire,
Output Loop-Powered
(10-42Vdc)
|
Field Mount
Hockey-Puck
(head, pipe, relay-track, surface, and explosion-proof)
|
|
FDY 2-Wire PC-Programmable Frequency-to-DC Transmitter with Display
Get Data Sheet
fdy.pdf (277K ) |
Sets Up in One Minute, From One Software Window
Frequency
0.005Hz to 25KHz Ranges
Periods
40 microseconds to 200 seconds
Pulse Widths
0.2 milliseconds to 200 seconds
|
User-Configurable Display Shows Any Engineering Unit
4-20mA
|
2-Wire, Output Loop-Powered (12-42DC)
|
Field-Mount
Hockey-Puck
(head, pipe, relay-track, surface, and explosion-proof)
|