Break out analog and discrete process, status and diagnostic signals from smart multivariable transmitters and valves; monitor critical and safety-related loops; prevent costly false shutdowns; and warn of unwanted process or instrument fault conditions.

For more information, go to Problem Solvers Application Ideas.

Detailed product data sheets are available in PDF format by clicking on the product names below. PDF files require Adobe Reader, which can be downloaded from Adobe's Web site.

Featured Interface Solutions

Unit

Input

Output

Power

Mounting

Features

SSX 2-Wire, Loop-Powered HART Safety Series Isolators



Get Product Information and Installation Tools

Get exida SIL 3 Certificate

4-20mA
4-20mA into 100 ohms with HART digital data superimposed
1-5V into 1Mohm
Isolates Loop, Lets HART Digital Signal "Pass Through"
4-20mA Isolated,
4-20mA into 600 ohms (with 24Vdc power); with HART digital data superimposed
2-Wire,
Loop-Powered
12-42DC
DIN Universal DIN-style housing mounts on 32mm G-type rail (EN50035) or 35mm Top Hat rail (EN50022)

FLB Flange bracket with top/bottom mounting holes

exida certified
IEC 61508:2010
SIL 3 capable

Isolates the analog loop, and lets the HART digital signal pass through unaffected


Unit 

Input

Output

Power

Mounting

Features

SST 4-Wire, Line-(Mains) Powered HART Safety Series Isolator and Splitter



Get Product Information and Installation Tools

Get exida SIL 3 Certificate

4-20mA
4-20mA into 100 ohms with HART digital data superimposed
1-5V into 1Mohm
Isolates Loop, Lets HART Digital Signal "Pass Through"
4-20mA Isolated,
4-20mA into 1000 ohms (with 24Vdc, 117Vac, or 230Vac power); with HART digital data superimposed 2x4-20mA into 600 ohms per channel (available with 4-20mA input only); HART digital data superimposed on Channel A only
4-Wire,
Line-Powered
24DC±10%
117AC50/60HZ,
±10%
230AC50/60HZ,
±10%
3 watts maximum for single channel models; 5 watts maximum for dual output channel models
DIN Universal DIN-style housing mounts on 32mm G-type rail (EN50035) or 35mm Top Hat rail (EN50022)

FLB Flange bracket with top/bottom mounting holes

exida certified
IEC 61508:2010
SIL 3 capable

Isolate and pass critical HART data

HART Splitter:
“Sharing” or
“Splitting” process
signals

Transmitter excitation: power a 2-wire transmitter


Unit 

Input

Output

Power

Mounting

Features

HIM HART® Interface Module


Get Product Information and Installation Tools
Accepts and "Reads" the HART Digital Protocol Signal that Rides on the 4-20mA Wires of a Smart HART Multivariable Transmitter or Valve
"Break Out" Analog Signals Representing the Multivariable Transmitter's Primary, Second, Third or Fourth Variables, or Smart Valve Position and Status Parameters
Two or three 4-20mA Signals

Optional Dual Relay Outputs Warn of Unwanted Process Conditions or Diagnostic Problems
High/Low Alarms
(Failsafe or Non-Failsafe)

Two Redundant MODBUS RTU (RS-485) Data Links

Digital Display Shows Process Status and Fault Messages
24Vdc

High-Density and RFI Resistant
Aluminum DIN-style
(G-type and Top Hat rails)

Convert HART non-primary measurements to analog signals

Works with every HART-compatible device

Dual process and/or diagnostic alarms (optional)

HART-to-MODBUS RTU converter (optional)

Sets up as primary master, secondary master or “listen” mode

Works in “Normal” and “Burst” HART modes

PC-programmable with FREE software and cable

Customizable display shows process status/diagnostics

Unit 

Input

Output

Power

Mounting

Features

HCS HART® Concentrator System HART-to-MODBUS Converter


Get Product Information and Installation Tools
Accepts and "Reads" the HART Digital Protocol Signal that Rides on the 4-20mA Wires of a Smart HART Multivariable Transmitter or Valve
Converts the HART Digital Signal to serial (RS-485) MODBUS RTU Communication Protocol to allow smart transmitters and valves to interface with MODBUS-based systems. 4-Wire,
Line-Powered
(24Vdc)
High-Density and RFI Resistant
Aluminum
DIN-style (G-type and Top Hat rails)

Convert HART to MODBUS RTU

Works with every HART-compatible device

Monitors primary and non-primary variables

PC-programmable with FREE software and cable

Unit

Communication

Transmission

Power

Frequency

Option

Housing

BULLET WirelessHART Adapter by MACTek

BULLET WirelessHART Adapter by MACTek

Get Product Information and Installation Tools

Platform:
WirelessHART capable network

Compliance:
Fully compliant HART 7.1 device. Backward compatible to HART 5 devices

HART
Sub-Devices:

Supports up to 8 wired HART sub-devices

RF Range: 235 meters outdoors, open air (normal)


RF Output Power: 10dBm

Series Loop Voltage Drop:
1.0Vdc-2.5Vdc (user-selectable in 0.5Vdc steps)

Series Loop Operating Current: 3.2mA to 25mA DC operating; Protected against over-voltage, over-current and reverse connections

External Power Operating Voltage:+7Vdc to +32Vdc; Reverse voltage protection

External Power Operating Current:<1mA; Maximum, 25mA

2.4GHz

Multidrop (Direct Power): 32mA DC maximum, 8 devices at 4mA DC; or 1 TCM

Multidrop (Loop Power): 24mA DC maximum, 6 devices at 4mA DC; or 1 TCM

Loop Current Monitoring Range: 3.2mA to 22mA DC, 1% Accuracy

Body:Aluminum alloy, RoHS corrosion coating, polyurethane enamel paint

Dome: Proprietary resin

Physical Connection:One, Male ½-inch NPT with internal poured seal

Electrical Connection:5 lead wires x 600mm (24-inch) long, exiting from male ½-inch NPT Opening

Ground: External earth grounding screw


Unit 

Input

Output

Power

Mounting

Features

HIT and HIX 2- and 4-Wire HART® Isolators


Get Product Information and Installation Tools
4-20mA
input with superimposed HART digital protocol signal
Isolates Loop, Lets HART Digital Signal "Pass Through"
4-20mA
output with superimposed HART digital protocol signal
HIT
4-wire line-powered
(24Vdc, 117Vac, 230Vac)

HIX
2-wire loop-powered
(12-42DC)
Thermoplastic DIN-style
(G-type and Top Hat rails)
Isolates the analog loop, and lets the HART digital signal “pass through” unaffected