Alarms Trips Provide on/off control, warn of trouble, or provide emergency shutdown by sending one or more alarm (relay) outputs when a monitored process signal falls outside of a selected high and/or low limit.

For more information, go to Problem Solvers Application Ideas and Capabilities.

New White Paper
NEW! Interactive White Paper
What can the "new generation" of safety-certified Single Loop Logic Solvers do for you? Find out by reading this informative white paper Safety Instrumented Systems: The "Logic" of Single Loop Logic Solvers ( 562K )


 

Detailed product data sheets are available in PDF format by clicking on the product names below. PDF files require Adobe Reader, which can be downloaded free from Adobe's Web site.

USB Cable Now Available for PC-Programmable Interface Instruments!
In addition to our FREE serial Configuration Cable, we now offer (for a nominal charge) a USB Communication Cable for Moore Industries' PC-Programmable Instruments. Get Data Sheet (535K)

Featured Interface Solutions
Model Input Output Power Mounting
STA 4-Wire SIL 2 Compliant Programmable Current/Voltage and RTD/Thermocouple Safety Trip Alarms

STA



Get Data Sheet
sta.pdf (1.1M)

NEW! Get Safety Trip Alarm White Paper
safety_instrumented_systems.pdf (562K)

Get TÜV Rheinland Certificate
tuv_certificate.pdf ( 55K)

Fast Set Up with On-Board Controls
Current
Any range from 0 to 50mA including:
0-20mA
4-20mA
10-50mA
Voltage
Any range from 0 to 10Vdc including:
0-5Vdc
1-5Vdc
0-10Vdc
Dual Process Relays and One Fault Relay

Process Relays #1 and #2 individually configure for:
High Alarm
Low Alarm
Normally Open
Normally Closed

Fault Relay #3 configures for:
Normally Open
Normally Closed

Combination Alarm and Transmitter with Optional Analog Output
0-21.6mA
-0.2-10.5V
(The analog output (-AO option) is not part of the safety path, and can not be used as a component in a SIS)

(All relays are fixed as Failsafe)

4-Wire
Line-Powered
(24Vdc or Universal for any range between 90-260Vac)
High-Density and RFI Resistant
Aluminum DIN-style
(G-type and Top Hat rails)
RTD
2-, 3-, 4-Wire
Platinum, Copper, Nickel
Thermocouple
J, K, E, T, R, S, N, C, B
Ohms
0-4000 ohms
Millivolts
-50 to +1000mV
SPA2 4-Wire Site- and PC-Programmable Current and Voltage; RTD and Thermocouple Limit Alarm Trips

SPA2

Get Data Sheet
spa2.pdf (889K )

Get Alarm Trips Tutorial
AlarmTripsTheUpsandDownsTutorial.pdf (685K )

Fast Set Up with Either On-Board Controls
or a PC

Current
Any range from 0 to 50mA including:
0-20mA
4-20mA
10-50mA
Voltage
Any range from 0 to 10Vdc including:
0-5Vdc
1-5Vdc
0-10Vdc
Dual Relays
Quadruple Relays

Fast Set Up with Either On-Board Controls or a PC
High Alarm
Low Alarm
Failsafe
Non-Failsafe
Normally Open
Normally Closed

Combination Alarm and Transmitter with Optional Analog Output
0-20mA
0-5Vdc
0-10Vdc
4-Wire
Line-Powered
(24Vdc, 110DC, Universal for any range between 90-260Vac)
High-Density and RFI Resistant
Aluminum DIN-style
(G-type and Top Hat rails)
RTD
2-, 3-, 4-Wire
Platinum, Copper, Nickel
Thermocouple
J, K, E, T, R, S, N, C, B
Ohms
0-4000 ohms
Millivolts
-50 to +1000mV
SPA 4-Wire Site-Programmable Current and Voltage; RTD and Thermocouple Limit Alarm Trips

SPA

Get Data Sheet
spa.pdf (1.2M )

Selectable with On-Board Controls
0-20mA
4-20mA
0-50mA
10-50mA
0-5Vdc
1-5Vdc
0-10Vdc
Special Ranges
Single Relay
Dual Relays
Triple Relays
Quadruple Relays

Selectable with On-Board Controls and Display Prompts
High Alarm
Low Alarm
Failsafe
Non-Failsafe
Normally Open
Normally Closed
Latching
Non-Latching

Combination Alarm and Transmitter with Optional Analog Output
0-20mA
0-5Vdc
Takes Any Power Supply
4-Wire, Universal Powered
(accepts 22-300Vdc or 90-260Vac)

CE approved unit comes with a 24Vdc, 117Vac or 230Vac power supply.
High-Density and RFI Resistant
Aluminum DIN-style
(G-type and Top Hat rails)
Any AC voltage range between 0-250VAC

Any AC current range between 0-5AAC
RTD
2-, 3-, 4-Wire
Platinum, Copper, Nickel
Thermocouple
J, K, E, T, R, S, N, B
Ohms
0-4000 ohms
Millivolts
-10 to +120mV
CPA 4-Wire PC-Programmable Current and Voltage; RTD and Thermocouple Limit Alarm Trip

CPA

Get Data Sheet
cpa.pdf (630K )

Sets Up in One Minute, From One Software Window.
Current
Any range from 0 to 50mA including:
0-20mA
4-20mA
10-50mA
Voltage
Any range from 0 to 10V including:
1-5Vdc
0-10Vdc
RTD
2-, 3-, 4-Wire
Platinum, Copper, Nickel
Thermocouple
J, K, E, T, R, S, N, C, B
Ohms
0 to 4000 ohms
Millivolts
-50 to +1000mV
Single Relay
Dual Relays

Configurable with PC Software
High Alarm
Low Alarm
Failsafe
Non-Failsafe
Normally Open
Normally Closed

Combination Alarm and Transmitter with Optional Analog Output
Any range from 0 to 20mA including:
0-20mA
4-20mA
Voltage
Any range from 0 to 10Vdc including:
1-5Vdc
0-10Vdc
4-Wire
Line-Powered
(24Vdc, 117Vac, or 230Vac)
High-Density and RFI Resistant
Aluminum DIN-style
(G-type and Top Hat rails)

ECA-DIN 4-Wire Current and Voltage Alarm

ECA-DIN

Get Data Sheet
eca_din.pdf (101K )

4-20mA
1-5V
0-5AAC
Dual Relays

Field-Configurable with Jumpers
High Alarm
Low Alarm
Failsafe
Non-Failsafe
4-Wire,
Line-Powered
(24Vdc, 117Vac, 230Vac)
High-Density and RFI-Resistant
Aluminum DIN-style
(G-type and Top Hat rails)
SPA 4-Wire Site-Programmable HART Loop Monitor and Alarm

SPA

Get Data Sheet
spa_hart.pdf (267K )

Monitor a Process Variable and "Health" of a HART Transmitter or Valve
Accepts a HART digital input from a pressure, temperature, level, flow or multivariable transmitter or from a smart HART valve.
Dual Relays
Quadruple Relays

Selectable with On-Board Controls
High Alarm
Low Alarm
Failsafe
Non-Failsafe
Normally Open
Normally Closed
Latching
Non-Latching
HART Fault Alarm

Analog Output
Proportional to transmitter measurement, any multivariable transmitter measurement or valve stem position
Takes Any Power Supply
4-Wire, Universal Powered
(accepts 22-300Vdc or 90-260Vac)

CE approved unit comes with a 24Vdc, 117Vac or 230Vac power supply.
High-Density and RFI Resistant
Aluminum DIN-style
(G-type and Top Hat rails)

DDA 4-Wire Current and Voltage Alarm

DDA

Get Data Sheet
dda.pdf (146K )

0-20mA
1-5mA
4-20mA
10-50mA
0-1Vdc
0-5Vdc
1-5Vdc
0-10Vdc
Single Relay
Dual Relays

Field-Configurable with Jumpers
High Alarm
Low Alarm
Failsafe
Non-Failsafe
4-Wire,
Line-Powered
(24Vdc)
Real-Time Process Readout
Thermoplastic DIN-style
(Top Hat rail)
HFA 4-Wire HART Fault® Alarm

HFA

Get Data Sheet
hfa.pdf (111K )

Monitor the "Health" of a HART Instrument
HART
Accepts a HART digital input from a temperature, pressure, level, flow or multivariable transmitter.
Single-Pole/Double Throw HART Fault Alarm
High Alarm
Low Alarm
Failsafe
Non-Failsafe
Latching
Non-Latching
4-Wire,
Line-Powered
(18-30Vdc)
High-Density and RFI Resistant
Aluminum DIN-style
(G-type and Top Hat rails)