What's New


Blog


«December 2017»
MonTueWedThuFriSatSun
27282930123
45678910
11121314151617
18192021222324
25262728293031
1234567

Get Warnings on Sensor Resistance Level Increases With the THZ3 and TDZ3

Get Warnings on Sensor Resistance Level Increases With the THZ3 and TDZ3
Under normal conditions, the loop resistance of a thermocouple will gradually change with temperature. However, exposure to extreme high temperatures can cause the resistance to increase at a substantial rate. This can be a sign of several issues within your sensor. For example, high temperatures can release impurities and chemicals within the thermocouple wire insulation that diffuses into the thermocouple metal and changes its characteristics. This can possibly lead to resistance increases as the thermocouple insulation material is breaking down.
Published: August 7, 2015

Get Tips on Temperature Measurement Accuracy From New White Paper

Get Tips on Temperature Measurement Accuracy From New White Paper
For many temperature applications, getting a high level of accuracy is vital. A new white paper from Moore Industries highlights how plant and site engineers can ensure the most accurate temperature measurement for critical applications. Available for download from the Moore Industries website, “A Practical Guide to Improving Temperature Measurement Accuracy details steps that can also help end users improve the stability of their measurements and reduce calibration costs.
Published: June 25, 2015

E-HELP: Differential Temperature Measurement with Two RTDs

E-HELP: Differential Temperature Measurement with Two RTDs

Q: I am looking for a differential temperature transmitter. We have used the SPT in the past and know that it will work, but I don’t know if you can use two inputs of two different 4-wire RTDs with the SPT.

A: The SPT has only four input terminals; therefore the number of RTD wires is limited. For differential temperature one RTD can be a 3-wire and the other RTD can only be a 2-wire. The lead length compensation wire of the 3-wire connection compensates for the lead length of both RTDs. This is only useful if you make sure that all five wires have the identical resistance.

Published: June 16, 2015

Measuring Discrete Inputs Using the BULLET and the TCM

Measuring Discrete Inputs Using the BULLET and the TCM
Having a WirelessHART gateway available provides end users with many potential uses. One of them is in moving discrete inputs via the WirelessHART gateway in a simple and affordable manner. This can be easily accomplished using the unique capabilities of Moore Industries’ TCM Temperature Concentrator Monitor and the BULLET WirelessHART Adapter.
Published: May 28, 2015

The WORM Adds Value Beyond Flexibility

The WORM Adds Value Beyond Flexibility
The original goal when creating the WORM Flexible Temperature Sensor was to provide a sensor that could be cut in the field to accommodate various size wells and assemblies. Experience has proven this design helps with other obstacles in the field:
Published: May 13, 2015
RSS
First 3456789101112