EHELP: Are the STA and SPA2 process alarm relays configurable as Failsafe?

EHELP: Are the STA and SPA2 process alarm relays configurable as Failsafe?
Q: For the STA 4-Wire SIL 2 and SIL 3 Compliant Programmable Current/Voltage and RTD/Thermocouple Safety Trip Alarms, can the process alarm relays be configured as Failsafe?  Can the process relay output of the SPA2-TRPRG be configured Failsafe?
Published: November 15, 2016

EHELP: SPA Power Consumption

EHELP: SPA Power Consumption

Q:  We are considering ordering the Moore Industries SPA/0-100mV/2 PRG/U/-SOL [DIN]. Can we power it using 24VDC? If so, what is the power consumption and how do we terminate? Also, can you please confirm whether this unit is Class 1 Div2, group A,B,C,D?

Published: September 13, 2016

EHELP: SPA2 Tank Application

EHELP: SPA2 Tank Application

Q:  Do you have a signal alarm unit for a tank level application? I need it to meet the following requirements:

  • Input signal accepts 4-20mA.
  • Contacts opened or relay de-energized @ EL 208 ft.
  • Equipped with up to four alarm trip relays.  
  • Individually configured for: set point, high or low trip, normally open or normally close, failsafe or non-failsafe, and latching or non-latching.
  • ■ Deadbands adjustable over 100% of span.
  • ■ Output relay equipped with form C contacts rated at 10A, 120VAC.
  • ■ All operating parameters adjustable from the front panel keypad.
  • ■ Operate on a 120V 60 Hz power source
  • ■ Capable of supplying 24V dc power to two-wire transmitters.
Published: August 23, 2016

New and Improved: "Alarm Trips: The Ups and Downs" Technical Paper

New and Improved: "Alarm Trips: The Ups and Downs" Technical Paper

Nowadays just having an effective alarm trip solution may not be enough.  Pushing forward in ways to protect life, community, environment and facilities, the process industry is experiencing dramatic increases in the need for functionally safe solutions. Moore Industries’ technical paper Alarm Trips: The Ups and Downs has been expanded with added material on this topic and more.