EHELP: Can the ECT-DIN, be configured for a 4-20mA input and 4-12mA split range output?

EHELP: Can the ECT-DIN, be configured for a 4-20mA input and 4-12mA split range output?

Q. Can the ECT-DIN, configured for 4-20mA input and 4-20mA output, be calibrated to give 4-12mA output when the input is 4-20mA so that the output is 1/2 the input? We have a radio I/O signal that is scaled to 4-20mA for 0-65, 535raw units. When sent to the PLC over Modbus, it can't be read properly since the maximum register value size for the PLC is limited to 32767.
Published: March 29, 2017

Announcing the SFY Functional Safety Frequency-to-DC Transmitter with Display and SIL 3 Capability

Announcing the SFY Functional Safety Frequency-to-DC Transmitter with Display and SIL 3 Capability
Moore Industries is proud to announce the new SFY Functional Safety Frequency-to-DC Transmitter with display including SIL 3 capability. The 2-wire (loop-powered) SFY is ideal for use in your Safety Instrumented System (SIS) in a wide range of process and factory automation monitoring applications and as part of the FS Functional Safety Series providing reliable and accurate monitoring of frequency or pulse signals in SIS. The SFY is approved for single use in SIS up to SIL 2 and in a redundant architecture (1oo2, 2oo3, etc.) up to SIL 3.
Published: January 31, 2017

SPA2IS Controls and Monitors Wet Wells

Wastewater Treatment Application

SPA2IS Controls and Monitors Wet Wells
Municipalities often have several wet well locations around a city that pump waste from low lying areas up to main sewage veins that feed waste treatment plants.  Level instruments monitor the wet well level and controllers then engage the grinder pumps.  Since wet wells contain waste, volatile gasses such as methane require that these level instruments be rated for use in Class I, Div 1 environments.
Published: January 9, 2017

EHELP: STA Analog Output Protection

EHELP: STA Analog Output Protection
Q:  In specifying the Moore STA / HLPRG / 3PRG / U / -AO [DIN] our end user has a concern about electrical protection for the analog output. The desire is to use 4-20mA Output Loop Voltage sourced by DCS for the AO; however, this voltage may fault at up to 132 VAC. Should our design add fuse protection in the external voltage circuit upstream of the STA to protect it from these surges? Or does the STA include features that protect it from these faults?
Published: October 4, 2016

EHELP: What is the 2 in IPT2

EHELP: What is the 2 in IPT2

Q:  A field tech told me he installed an IPT2/4-20MA/3-15PSIG/20PSIG/-FA1 [DIN] unit.  In the product bulletin I don't see a purpose for the trailing "2" in the model name, and I don't see an explanation for -FA1.

Published: September 20, 2016