EHELP: Is There a Solution to Pass Hart Data Through an Isolator to My DCS?

EHELP: Is There a Solution to Pass Hart Data Through an Isolator to My DCS?
Q. I want to share a critical pressure signal with my DCS that is now part of our safety instrumented system (SIS) and have a two part question. First, do your isolators pass the HART diagnostic data that comes from my SIS smart pressure transmitter? Second, if there is a total failure of the pressure transmitter, where will the output of the isolator go to that is feeding my DCS?
Published: May 10, 2017

EHELP: What is the maximum impedance that the output of an output loop powered ECT-DIN can drive?

EHELP: What is the maximum impedance that the output of an output loop powered ECT-DIN can drive?
Q. What is the maximum impedance that the output of an output loop powered ECT-DIN can drive?
Published: April 27, 2017

A Reason to Demand Moore Reliability: TCA Thermocouple Alarm With 36 Years Continuous Service

A Reason to Demand Moore Reliability: TCA Thermocouple Alarm With 36 Years Continuous Service

Moore Industries' Director, Sales Support Matt Moren received an inquiry from a customer regarding a replacement for an Alarm Trip. The customer is a world-leading multi-billion dollar industrial gases company that has been in operation for over 75 years focusing on the industrial gases business providing atmospheric and process gases as well as related equipment for manufacturing markets including refining and petrochemical, metals, and electronics among other businesses.

Published: April 17, 2017

EHELP: How do I account for the linearization function representing the volume measurement in a cone-shaped bottom tank at various levels?

EHELP: How do I account for the linearization function representing the volume measurement in a cone-shaped bottom tank at various levels?

Q.  We want to use a SPD Field-Mount Programmable Loop Display with a radar transmitter mounted on the top of a cone-shaped bottom tank that outputs 4-20mA signal, and we would like to know how to account for the linearization function representing the volume measurement in the tank at various levels?

Published: April 12, 2017

EHELP: Can the ECT-DIN, be configured for a 4-20mA input and 4-12mA split range output?

EHELP: Can the ECT-DIN, be configured for a 4-20mA input and 4-12mA split range output?

Q. Can the ECT-DIN, configured for 4-20mA input and 4-20mA output, be calibrated to give 4-12mA output when the input is 4-20mA so that the output is 1/2 the input? We have a radio I/O signal that is scaled to 4-20mA for 0-65, 535raw units. When sent to the PLC over Modbus, it can't be read properly since the maximum register value size for the PLC is limited to 32767.
Published: March 29, 2017