Explore Moore Industries' Entire White Paper Archive

Explore Moore Industries' Entire  White Paper Archive
Make sure you check out the Technical White Papers section of the Moore Industries website. 
Published: January 15, 2018

STA 1oo2 Voting with High Availability

STA 1oo2 Voting with High Availability
A customer has a Safety Instrumented Function they need to implement with two independent level transmitters (radar), each wired to a separate STA Functional Safety Trip Alarm. The process will trip if either level reaches the set point, for example a 1 out of 2 (1oo2) voting. However, if the alarm trip (STA) detects an input or unit fault. The customer did not want the process to trip. Instead they wanted to take the faulty unit out of service leaving the process running with the one good level and alarm trip. 
Published: November 28, 2017

PSD: A Loop Indicator for All Applications and All Stockrooms

PSD: A Loop Indicator for All Applications and All Stockrooms

Most process loop indicators do a sufficient job indicating a process variable in the field.  But what happens when signals are from level transmitters that sit atop vessels where the level is not linear with volume and the loop indicator needs to display the volume?  Or what if yesterday’s installation area was a Div 2/Zone 2 location and today it’s a Div 1/Zone 0/1 location?  And what happens when you need to setup 50 loop indicators with tedious push button set up or a small HART handheld screen? 

Published: November 7, 2017

Moore Reliability and Customer Satisfaction Proven in the Field

Moore Reliability and Customer Satisfaction Proven in the Field

Recently a customer contacted Moore Industries with a request to reorder temperature transmitters and signal conditioners. They wanted to purchase identical products because of their reliability and were hoping the temperature transmitters and signal conditioners were still available. The products were purchased more than 25 years ago!  

Published: August 28, 2017

Temperature Q&A with JR Madden: Thermocouples

Temperature Q&A with JR Madden: Thermocouples
Q: A Type K thermocouple is being used in a high temperature furnace environment for temperature measurementHowever the Type K thermocouple is drifting too much. Is there something I could do so I don't have to change it out frequently or is there another type of thermocouple I could use?
Published: May 22, 2017